Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
Lancet Reg Health West Pac ; 26: 100533, 2022 Sep.
Article in English | MEDLINE | ID: covidwho-2086523

ABSTRACT

Background: Regular repeat surveillance testing is a strategy to identify asymptomatic individuals with SARS-CoV-2 infections in high-risk work settings to prevent onward community transmission. Saliva sampling is less invasive compared to nasal/oropharyngeal sampling, thus making it suitable for regular testing. In this multi-centre evaluation, we aimed to validate RT-PCR using salivary swab testing of SARS-CoV-2 for large-scale surveillance testing and assess implementation amongst staff working in the hotel quarantine system in Victoria, Australia. Methods: A multi-centre laboratory evaluation study was conducted to systematically validate the in vitro and clinical performance of salivary swab RT-PCR for implementation of SARS-CoV-2 surveillance testing. Analytical sensitivity for multiple RT-PCR platforms was assessed using a dilution series of known SARS-CoV-2 viral loads, and assay specificity was examined using a panel of viral pathogens other than SARS-CoV-2. In addition, we tested capacity for large-scale saliva testing using a four-sample pooling approach, where positive pools were subsequently decoupled and retested. Regular, frequent self-collected saliva swab RT-PCR testing was implemented for staff across fourteen quarantine hotels. Samples were tested at three diagnostic laboratories validated in this study, and results were provided back to staff in real-time. Findings: The agreement of self-collected saliva swabs for RT-PCR was 84.5% (95% CI 68.6 to 93.8) compared to RT-PCR using nasal/oropharyngeal swab samples collected by a healthcare practitioner, when saliva samples were collected within seven days of symptom onset. Between 7th December 2020 and 17th December 2021, almost 500,000 RT-PCR tests were performed on saliva swabs self-collected by 102 staff working in quarantine hotels in Melbourne. Of these, 20 positive saliva swabs were produced by 13 staff (0.004%). The majority of staff that tested positive occurred during periods of community transmission of the SARS-CoV-2 Delta variant. Interpretation: Salivary RT-PCR had an acceptable level of agreement compared to standard nasal/oropharyngeal swab RT-PCR within early symptom onset. The scalability, tolerability and ease of self-collection highlights utility for frequent or repeated testing in high-risk settings, such as quarantine or healthcare environments where regular monitoring of staff is critical for public health, and protection of vulnerable populations. Funding: This work was funded by the Victorian Department of Health.

2.
EBioMedicine ; 79: 103983, 2022 May.
Article in English | MEDLINE | ID: covidwho-1778093

ABSTRACT

BACKGROUND: High testing rates and rapid contact tracing have been key interventions to control COVID-19 in Victoria, Australia. A mobile laboratory (LabVan), for rapid SARS-CoV-2 diagnostics, was deployed at sites deemed critical by the Victorian State Department of Health as part of the response. We describe the process of design, implementation, and performance benchmarked against a central reference laboratory. METHODS: A BSL2 compliant laboratory, complete with a class II biological safety cabinet, was built within a Mercedes-Benz Sprinter Panel Van. Swabs were collected by on-site collection teams, registered using mobile internet-enabled tablets and tested using the Xpert® Xpress SARS-CoV-2 assay. Results were reported remotely via HL7 messaging to Public Health Units. Patients with negative results were automatically notified by mobile telephone text messaging (SMS). FINDINGS: A pilot trial of the LabVan identified a median turnaround time (TAT) from collection to reporting of 1:19 h:mm (IQR 0:18, Range 1:03-18:32) compared to 9:40 h:mm (IQR 8:46, Range 6:51-19:30) for standard processing within the central laboratory. During deployment in nine rural and urban COVID-19 outbreaks the median TAT was 2:18 h:mm (IQR 1:18, Range 0:50-16:52) compared to 19:08 h:mm (IQR 5:49, Range 1:36-58:52) for samples submitted to the central laboratory. No quality control issues were identified in the LabVan. INTERPRETATION: The LabVan is an ISO15189 compliant testing facility fully operationalized for mobile point-of-care testing that significantly reduces TAT for result reporting, facilitating rapid public health actions. FUNDING: This work was supported by the Department of Health, Victoria State Government, Australia.


Subject(s)
COVID-19 , SARS-CoV-2 , Australia , COVID-19/diagnosis , COVID-19/epidemiology , COVID-19 Testing , Humans , Point-of-Care Testing , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL